Table 13 Required thermal characteristics of windows, doors and skylights Zone 4 <3000 Zone 5 3000 - 3999 Zone 6 4000 - 4999 Zone 7A 5000 - 5999 Zone 7B 6000 - 6999 Zone 8 >7000 Typical Locations Vancouver, BC Kamloops, BC Kelowna, BC Toronto, ON Prince Rupert, BC Lethbridge, BC Ottawa, ON Montreal, QC Halifax, NS Calgary, AB Regina, SK Winnipeg, MB Quebec City, QC Edmundston, NB Cold Lake, AB Whitehorse, YK NWT and Nunavut Thermal Characteristics Heating degree-days of building location,1 in celsius degree-days Climate Zone Heating-degree days Maximum U-value, W/(m2•K) 1.60 1.60 1.40 1.40 25 25 29 29 2.40 2.40 Windows and Doors2 1.80 Minimum Energy Rating 21 Skylights 1.80 21 Maximum Overall Thermal Transmittance 2.90 2.90 2.70 2.70 Notes to Table 13 1. See NBC 1.1.3.1. 2. Except skylights and glass block assemblies