Table 6 Mortar mix proportions (by volume) Permissible Use of Mortar Portland Cement Masonry Cement (Type H) All locations1 1 ⁄2 to 1 1 — 1 — 1 All locations1, except foundation walls and piers — 1 — 1 — 1 All locations, except loadbearing walls of hollow units 1 — 11⁄4 to 21⁄2 All non-loadbearing partitions and all loadbearing walls of solid units except foundation walls 1 — 21⁄4 to 4 — — 1 Lime Aggregate ⁄4 to 1⁄2 ⁄2 to 11⁄4 Not less than 21⁄4 and not more than 3 times the sum of the volumes of the cement and lime Note to Table 6 1. Must not be used for sand-lime brick or concrete brick.