The substrate to which an EIFS is attached is not considered part of the EIFS. However, the substrate must be compatible with the EIFS, and be properly designed and installed for the EIFS to perform acceptably. EIFS components are shown in Figure 115.
EIFS are often applied to substrates treated with a moisture, air and/or vapour barrier. Barriers that are compatible with EIFS are provided or recommended by manufacturers. A typical EIFS arrangement with a vertical joint between panels is shown in Figure 116.
115 Basic exterior insulation and finish system (EIFS) components Substrate* treated with water-resistant coating Adhesive Insulation Base coat with mesh Finish coat
* Substrate is shown for clarity: it is not part of the EIFS
116 Components of an exterior insulation and finish system (EIFS)
vertical drainage channels in insulation water resistant barrier membrane (WRB) finish coat two-stage joint for pressure equalization and drainage at joints between panels insulation base coat with mesh